system impedance造句
例句與造句
- Adaptive protection device uses local information only and can only adapt to changes of system impedance of less area of power system
保護裝置自適應(yīng)由于只利用本地信息,只能適應(yīng)較小范圍的系統(tǒng)運行方式變化。 - Comparing with passive filter , apf has many advantages , which is insensitive to system impedance and can be used to compensate harmonics . apf plays an important role in eliminating harmonic
有源電力濾波技術(shù)與無源濾波技術(shù)相比,具有受電網(wǎng)阻抗影響小、能夠動態(tài)補償?shù)葍?yōu)點,在治理諧波污染方面發(fā)揮重要作用。 - Comparing with passive filters , apf have many advantages , which are not easily affected by system impedance and can be used to dynamically compensate harmonic . apf will play an important role in eliminating harmonics
有源電力濾波器技術(shù)與無源濾波器技術(shù)相比,具有受電網(wǎng)阻抗影響小、能夠動態(tài)補償?shù)葍?yōu)點,將在治理諧波污染方面發(fā)揮主導(dǎo)作用。 - Via communication network , adaptive protection system uses information of the system , realizing strategy of adaptive protection function and adatpvie protection algorithm . it can adapt to various changes of system impedance of power system and get the optimal protecting effect
保護系統(tǒng)自適應(yīng)通過通信網(wǎng)絡(luò),利用系統(tǒng)信息、自適應(yīng)保護功能實現(xiàn)策略與自適應(yīng)保護算法,能適應(yīng)電力系統(tǒng)各種運行方式的變化,達到最佳保護效果。 - The adaptive setting algorithm and realizing strategy of adaptive protection function use local information of adaptive protection device , information of substation , status messages and topology connection relations coming from scada system offered by centralized control center to adapt to changes of topology structure , system impedance and fault type by amending the settings on line . the adatpvie protection algorithm of the device is adaptive three - step current protection
所提出的自適應(yīng)整定算法、系統(tǒng)級自適應(yīng)保護功能實現(xiàn)策略綜合利用供配電線路自適應(yīng)保護裝置本地信息、變電站站內(nèi)信息與集控中心借助scada系統(tǒng)提供的一次、二次設(shè)備狀態(tài)信息及拓撲連接關(guān)系,自動在線計算并修正保護整定值,實現(xiàn)了對電力系統(tǒng)拓撲結(jié)構(gòu)、運行方式及故障類型變化的自適應(yīng)。 - It's difficult to find system impedance in a sentence. 用system impedance造句挺難的
- By analyzing the refraction 、 reflection process of fault transient current traveling wave of high voltage and characteristics of refraction 、 reflection coefficient systematically , a new fault location method of single ended traveling wave is presented . it can not only identify the reflection wave for fault location efficiently , but also not be affected by the structure and length of line . fault earthed resistance 、 fault type 、 system impedance and can locate fault in adjacent areas accurately
論文深入地分析了高壓線路故障暫態(tài)電流行波的波折、反射過程以及折、反射系數(shù)的特點,提出了新的單端行波故障測距方法,它不僅能夠有效地識別出測距所用的反射波,而且?guī)缀醪皇芫€路結(jié)構(gòu)、長短、故障接地電阻、故障類型、系統(tǒng)阻抗的影響,在近區(qū)仍可以準確地進行測距;同時模擬阻波器的特征,設(shè)計了低通數(shù)字濾波器,對通過了低通數(shù)字濾波器的暫態(tài)故障電流行波再次進行小波分析,并利用本文提出的單端行波故障測距方法進行故障定位,結(jié)論是所提出的測距方法在實際應(yīng)用中仍是有效的。